Equipped with ten unique safety-enhanced ECG posts, the ESA620 offers simulation of ECG and performance waveforms so both electrical safety and basic tests on patient monitors can be performed with a single connection. When combined with optional Ansur computer-based software, the ESA620 allows for test procedure automation, the capture of results and comparison to standard limits, printed reports, and total digital data management. Superior compliance with multiple standards: IEC60601:2005, EN62353, VDE 751, ANSI/AAMI ES1:1993, NFPA-99, AN/NZS 3551, IEC61010. Expanded leakage ranges through 10,000 µA.
Dual-lead resistance, leakage, and voltage tests. AC only, dc only and true-rms leakage readings. 100 % and 110 % mains voltage for mains on applied part (lead isolation) test.200 mA and 25 A ac PE test current. DSP filter technology for improved accuracy in leakage measurements.
Easy-to-use applied parts (ECG) connections. Insulation posts on applied parts connections. Varying insulation test voltage 500 V dc and 250 V dc. CE, C-TICK and CSA for USA and Canada. Designed, tested, and built to incomparable Fluke quality standards. 90 V to 132 V ac rms 180 V to 264 V ac rms. 0 V to 300 V ac rms. ± (2 % of reading +2 LSD). Two-terminal mode test current/range and accuracy. 0.0 to 2.0 ± (2 % of reading + 0.015). 10 A to 25 A ac. 0.0 to 0.2 ± (2 % of reading + 0.015) 0.2 to 2.0 ± (5 % of reading + 0.015). Four-terminal mode test current/range and accuracy. 0.0 to 2.0 ± (2 % of reading + 0.005). 0.0 to 0.2 ± (2 % of reading + 0.005) 0.2 to 2.0 ± (5 % of reading + 0.005). 0 A to 20 A. ± 5 % of reading ± 2 counts or. 2 A, whichever is greater. 15 A to 20 A, 5 min on/5 min off 10 A to 15 A, 7 min on/3 min off 0 A to 10 A continuous. AC + DC (True-rms) AC only DC only.Patient load selection (input impedance). AAMI ES1-1993 IEC 60601 IEC 61010. 0 µA to 199.9 µA 200 µA to 1999 µA 2 mA to 10 mA. DC to 1 kHz 1 kHz to 100 kHz 100 kHz to 1 MHz.
± (1 % of reading + 1 µA) ± (2 % of reading + 1 µA) ± (5 % of reading + 1 µA). Earth (ground wire) Chassis (enclosure) Patient (lead to ground) Patient auxiliary (lead to lead) Mains on applied part (lead isolation) Direct equipment Direct applied part Alternative equipment Alternative applied part Accessible Point to point. Mains on applied part test voltage.
110 % of mains at 230 V for IEC 60601 100 % of mains for AAMI at 115 V per AAMI 100 % of mains at 230 V per 62353. 10 µA to 199 µA 200 µA to 1999 µA 2 mA to 20 mA.
± 10 % of reading ± (2 counts or 20 µA, whichever is greater). 0.5 M to 20 M.± (2 % of reading + 2 counts). 20 M to 100 M. ± (7.5 % of reading + 2 counts). 500 V dc 250 V dc. Mains-PE, AP-PE, Mains- PE, Mains-NE (non-earthed accessible conductive part) and AP- NE (non-earthed accessible conductive part).
± 2 % ± 5 % for amplitude of 2 Hz square wave only, fixed at 1 mV Lead II configuration. 30, 60, 120, 180, and 240.
Square wave (50 % duty cycle) (Hz). 10, 40, 50, 60, and 100. Pulse (63 ms pulse width). Mains voltage inlet power range.
90 to 132 V ac rms. 180 to 264 V ac rms. Dimensions (L x W x H). 31 cm x 23 cm x 10 cm (12.2 in x 9 in x 2.9 in). 4.7 kg (10.25 lb). 10 °C to 40 °C. 20 °C to 60 °C. 10 % to 90 % non-condensing. Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our. Please don't hesitate to. For a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet. Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment.Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more! We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. (Certain orders may take longer for processing due to comprehensive final service inspections). The item "Fluke ESA620 115 VAC Electrical Safety Analyzer Medical Equipment Tester ESA-620" is in sale since Tuesday, September 17, 2019.